Minutes, IBIS Quality Committee 29 Jul 2008 11-12 AM EST (8-9 AM PST) ROLL CALL Adam Tambone Anders Ekholm, Ericsson Barry Katz, SiSoft Benny Lazer Benjamin P Silva Bob Cox, Micron * Bob Ross, Teraspeed Consulting Group Brian Arsenault David Banas, Xilinx * Eckhard Lenski, Nokia Siemens Networks Eric Brock Guan Tao, Huawei Technologies Gregory R Edlund Hazem Hegazy Huang Chunxing, Huawei Technologies John Figueroa John Angulo, Mentor Graphics Katja Koller, Nokia Siemens Networks Kevin Fisher Kim Helliwell, LSI Logic Lance Wang, IOMethodology Lynne Green * Mike LaBonte, Cisco Systems Mike Mayer, SiSoft * Moshiul Haque, Micron Technology Peter LaFlamme Randy Wolff, Micron Technology Radovan Vuletic, Qimonda Robert Haller, Enterasys Roy Leventhal, Leventhal Design & Communications Sherif Hammad, Mentor Graphics Todd Westerhoff, SiSoft Tom Dagostino, Teraspeed Consulting Group Kazuyoshi Shoji, Hitachi Sadahiro Nonoyama Everyone in attendance marked by * NOTE: "AR" = Action Required. -----------------------MINUTES --------------------------- Mike LaBonte conducted the meeting. Call for patent disclosure: - No one declared a patent. AR Review: - Anders create example IBIS file with golden waveforms - TBD, long term New items: Continued review of the IBIS Quality Specification: 5.3.2 {LEVEL 3} I-V tables have correct typ/min/max order - Moshiul: DDR3 has compensation, can make the curves nearly overlay. - We accepted this check with minor typographical edits. 5.3.3 {LEVEL 3} I-V tables have reasonable numerical range - This is marked for deletion - IBISCHK warns above 10 amps - Bob: Extrapolate at lower slope instead of truncate - Usually limit at a couple of amps - Bob: Sometimes waivers are appropriate. We changed checks 5.3.2-10 from LEVEL 3 to LEVEL 2 5.3.8. {LEVEL 2} I-V tables do not exhibit stair-stepping - We discussed causes of stair stepping - Mostly number truncation artifacts. - Bob: Some devices can have one or more real steps. - Minor clarifications made to the text. 5.3.9. {LEVEL 2} Combined I-V tables are monotonic - Updated comments regarding IBISCHK and file versions. - Parser bug 94 fixed now. - Added warning that IBISCHK reports only first violation. 5.3.10. {LEVEL 3} [Pulldown] I-V tables pass through zero/zero - Better explanation of zero/zero. - How to word table votage vs. real voltage. - Moshiul: Does 0V have to be in the table? - Mike: IBISCHK uses 1uA as the standard for non-zero current - Comments about ODT should not apply to a Pullup/Pulldown check - Mike: Some models use ODT cancellation in Pulldown instead of Submodel - Minor clarifications made. 5.3.11. {LEVEL 2} [Pullup] I-V tables pass through zero/zero - New check added - Pullup needs this check as much as Pulldown does. - We copied from 5.3.10 AR: Mike post 1.1ag IQ spec version Moshiul: IQ does not cover [Series MOSFET] - We will discuss this next meeting Next meeting: 05 Aug 2008 11-12 AM EST (8-9 AM PST) Meeting ended at 12:01 PM Eastern Time.